Littelfuse 460-15 Voltage Monitor Product Description

The Models 460-14 and 460-15 are designed to protect 3-phase loads from damaging power conditions. Its wide operating range, combined with UL, cUL and CE compliance, enables quick access to domestic and global markets.

A unique microcontroller-based voltage and phase-sensing circuit constantly monitors the 3-phase voltages to detect harmful power line conditions. When a harmful condition is detected, the MotorSaver’s output relay is deactivated after a specified trip delay. The output relay reactivates after power line conditions return to an acceptable level for a specified amount of time (restart delay). The trip and restart delays prevent nuisance tripping due to rapidly fluctuating power line conditions.

The Models 460-14 and 460-15 automatically sense whether they are connected to a 190-240V 60Hz system, a 440-480V 60Hz system, or a 380-416V 50Hz system. An adjustment is provided to set the nominal line voltage from 190-240 or 380-480VAC. Motor control is accomplished with one NO contactor and one NC contactor (Model 460-14) or two NO contactors (Model 460-15). Other adjustments include a 1-30 second trip delay, a 1-500 second restart delay, and a 2-8% voltage unbalance trip point adjustment.

Littelfuse 460-15 Voltage Monitor Typical Applications

  • Fans
  • Compressors
  • HVAC
  • Heat Pumps
  • Well Pumps
  • Sump Pumps
  • Small Conveyor Motors
  • Oil Rigs

Littelfuse 460-15 Voltage Monitor Features

  • Protects Motor From:
    • Loss of any Phase
    • Low Voltage
    • High Voltage
    • Voltage Unbalance
    • Phase Reversal
    • Rapid Cycling
  • Isolated Output Contacts: 1 NO and 1 NC (460-14) 2 NO (460-15)
  • Standard Surface Mount -OR-
  • Opt. DIN Rail Mount
  • Standard 1-500 sec. Variable Restart Delay
  • Standard 2-8% adj. Voltage Unbalance Trip Point
  • Standard 1-30 sec. Variable Trip Delay
  • Two 8 Amp General Purpose Form C Relays
  • UL and cUL Listed
  • 5-Year Warranty
  • Made in USA
  • Universal Voltage Range from 109-480VAC 50/60Hz Provide the Versatility needed to Handle Global Applications.
  • Four Adjustment Pots Provide Flexibility for a Variety of Applications.
  • Diagnostic LEDs Indicate Trip Status and Make Troubleshooting a Snap.
  • Microcontroller-Based Circuitry Provides better Accuracy and Higher Reliability than Analog Designs.
  • Transient Protection Meets IEEE Standards and Allows Operation Under Tough Conditions.
  • Single-Phase Conditions are Detected Regardless of Regenerated Voltages.
  • Units Have One NO and One NC (-14) or Two NO (-15) Output Contacts.